Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13668752

- Product Categories
- Friendly Links
Information Name: | Fan coil fan coil manufacturers _ _ Ling of air conditioning |
Published: | 2015-06-09 |
Validity: | 0 |
Specifications: | As required |
Quantity: | |
Price Description: | |
Detailed Product Description: | It features a fan coil unit manufacturers, wholesale, unique hyperbolic windows and Staggered fin heat exchangers brass, fully strengthen air turbulence. Adjust the distance between the fins optimize pipeline design, to enhance the efficiency of heat transfer coil. 2-piece forging brass molding points, catchment, so chilled water coil and out of more uniform distribution, flow resistance is smaller, realize the full efficiency of the heat exchanger and greatly reduce flow resistance of the water system. 3, unit case box with high-strength high-quality galvanized steel sheet metal bending molding, strong corrosion resistance. Roof pressed against the inner wall of a thermoformed PE insulation cotton, to eliminate the phenomenon of cold bridges. Water tray at the bottom of the parcel once thermoformed PE insulation cotton, firmly attached to prevent secondary condensation occurs. 4, single-phase three-speed asynchronous motor as a permanent magnet unit Capacitive important power-driven parts. Motor center shaft are tempered by the strict chrome plated embalmed fan coil characteristics, rust wear. Permanently lubricated with high-precision NSK Japan closed rolling bearings containing paint, to ensure high efficiency and low noise requirements. 5, start capacitor is fully enclosed in a metal housing and integrated design with the motor housing, motor external leads to metal hose wear sleeve, in line with international fire safety standards. 6, extended drain pan design, the external piping valve connectors are protected in the drain pan, to ensure that no condensed water escape. 7, double inlet centrifugal forward wing galvanized steel quality wind turbines, the strict dynamic and static balance tone test, the air-handling to streamline transmission, reducing the generation of vortex airflow 68 fan coil units, greatly reduce noise generated when air flow friction, the unit run more smoothly and quiet. 8, before the unit factory have to undergo a rigorous operation, pressure and insulation tests, all of the motor terminals placed in special electrical box, to ensure a more secure unit is running. 13, each heat exchanger are into over 2.8Mpa pressure water leak detection and strict pressure tightness test, the unit allows the maximum working pressure 1.6Mpa, to ensure the performance and quality of each unit A, flush-mounted Horizontal Horizontal concealed fan coil fan coil units outlined the main control parameters chosen rated air volume, export static, input power, rated cooling capacity, rated for heat, noise, water resistance and the like. For dual-pipe water system (only applicable to seasonal or region only by air conditioning cooling heating or air conditioning system conversion) of the fan coil units, only configure a set of coils, winter heating / cooling dual-purpose models. For four-pipe water system (for heating / cooling air conditioning system frequently converted) fan coil units, heating and cooling should be configured two coils combined models. Second, the advantages of horizontal concealed fan coil 1, no return air box, can be opened by a ceiling fan coil air returns, easy cleaning and maintenance. 2, drain pan available upon request lengthened, ensure that the valve in the water tray. 3, drain pan made of stainless steel are available upon request. 4, quiet design, run quieter. Special design, you can return air remove the motor impeller for maintenance, cleaning and maintenance can coil when seasonal. 5, return air box can stay the new outlet on request. 6, a drain pan can be extended upon request, of the valve in the water tray. 7, drain pan made of stainless steel are available upon request. Third, horizontal concealed fan coil construction, water supply unit installed at the entrance points 1, shall be equipped with filters. In dry pipe system flushing coolant water when sewage allowed through the coils. To take over the highest point of the coil should be located exhaust, the lowest point of discharge devices should be located. 2. condensate discharge pipe fan coil units must have a certain slope, ensure no water drip pan. 3. Install the fan coil units can be found in the National Building Standard Design Atlas 01K403 "fan coil installation." Fan coil fan coil manufacturers _ _ Ling of Ling of air conditioning provided by the Texas Air Conditioning Equipment Co.. Ling of Texas Air Conditioning Equipment Co., Ltd. (www.sdldkt.com) (www.sdldkt.com) strong, credible, in Dezhou central air-conditioning industry has accumulated a large number of loyal customers. The company better work attitude and constantly improving Ling of innovative ideas will lead into the brilliant air conditioning and you work for a better future! |
Admin>>>
You are the 32872 visitor
Copyright © GuangDong ICP No. 10089450, Ling of Air Conditioning Equipment Co., Texas All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 32872 visitor
Copyright © GuangDong ICP No. 10089450, Ling of Air Conditioning Equipment Co., Texas All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility